像在多孔盤中快速讀取每一孔的螢光或冷光訊號:FLx800 支援 6 至 384 孔微孔盤,可進行 endpoint、kinetic 與多波長分析,適合細胞活性、基因報導、酵素反應、藥物篩選及 FRET/BRET 等研究。
用於螢光染劑、GFP 及 FRET 等訊號。Detects fluorescent dyes, GFP, FRET, and related signals.
用於 Luciferase、冷光報導及生物發光定量。Measures luciferase, luminescent reporters, and bioluminescence.
可追蹤訊號隨時間的變化。Tracks signal changes over time.
整合自動控制、資料分析及定量輸出。Integrates automated control, data analysis, and quantitative output.
支援 MTT、XTT、Resazurin 等細胞存活與毒性分析。Supports MTT-, XTT-, and Resazurin-based viability and cytotoxicity assays.
分析 Luciferase、GFP 或 β-galactosidase 活性。Analyzes luciferase, GFP, and beta-galactosidase reporter activity.
量測酵素活性及反應時間變化。Measures enzyme activity and reaction kinetics.
進行藥物篩選與劑量反應分析。Supports drug screening and dose-response analysis.
進行多波長螢光掃描及冷光定量。Performs multi-wavelength fluorescence scanning and luminescence quantification.
支援 FRET/BRET 蛋白質或分子結合實驗。Supports protein or molecular interaction studies using FRET/BRET.
於設定反應時間完成後讀取各孔訊號。Reads each well at the defined assay endpoint.
連續讀取訊號,分析反應速度與變化。Repeatedly reads signals to analyze reaction kinetics.
比較不同濃度處理之螢光或冷光結果。Compares fluorescence or luminescence across treatment concentrations.
高靈敏光學系統適合微量生物樣品。The sensitive optical system supports small-volume biological samples.
分析軟體可產生定量結果。Analysis software generates quantitative results.
操作貴重儀器前須先接受講習與認證。Complete training and certification before operating valuable instruments.
需登記之儀器設備請確實填寫使用紀錄。Record usage for instruments requiring registration.
準備微孔盤並依分析模式完成讀取。Prepare the microplate and run the selected assay mode.
關閉電源、維護空間與設備清潔,最後離場者關閉燈源。Turn off power, restore cleanliness, and ensure the last user turns off lights.
暫存資料置於 D 槽指定資料夾並盡可能當天以 CD 帶走;異常時通知管理員。Save temporary data in the designated D-drive folder, burn to CD when possible, and report abnormalities.
使用前須完成教育訓練與認證。Complete training and certification before use.
依規定完整填寫使用紀錄。Complete the required usage log.
使用後關閉儀器,最後離場者關閉所有燈。Turn off the instrument and all lights when leaving last.
使用後清潔並恢復空間與設備原狀。Clean and restore the space and equipment after use.
有毒物質須在 fume hood 中使用,化學品須清楚標示。Use toxic substances in a fume hood and label chemicals clearly.
以高壓滅菌或 5–10% 漂白水處理。Treat infectious liquids by autoclaving or 5–10% bleach.
養菌液、agar plate 與 EB 膠依規定包裝及滅菌。Package and sterilize culture waste, agar plates, and EB gels as required.
資料放 D 槽指定資料夾並盡可能燒錄 CD;異常通知管理員。Use the designated D-drive folder, burn data to CD when possible, and report issues.
| 使用者類別/服務 | User Category / Service | 收費標準 |
|---|---|---|
| 使用收費 | Usage Fees | 擬訂中 / Under development |
國際學術研究大樓 10 樓
共同實驗室
Shared Laboratory
10th Floor, International Academic Research Building