像先把混合物中的分子逐一分開,再替每個分子確認「質量身分」: ACQUITY ARC 液相層析系統可使用 C-18 管柱進行樣品分離, SQ Detector 2 則以正、負離子電噴灑模式量測質荷比, 適合小分子有機藥物、天然物及高解析質譜送測前的初步定性鑑別。
電噴灑質譜: 可使用正、負離子模式進行掃描,分析質量範圍 3000 Da 以下之樣品。 Electrospray ionization mass spectrometry can scan samples below m/z 3000 in positive and negative ion modes.
Waters SQ Detector 2: 採單四極桿質譜分析器,適合例行性的分子質量確認。 The Waters SQ Detector 2 is a single-quadrupole mass analyzer designed for routine mass confirmation.
正、負離子記錄: 可同時記錄正、負離子(ESI+/ESI−)模式。 Positive and negative ions (ESI+ / ESI−) can be recorded simultaneously.
質量範圍: 質量範圍可達 3000 Da,可觀察較高質量分子峰並提高質量確認信心。 The 3000 Da mass range allows detection of higher-mass peaks and supports more confident mass assignments.
ACQUITY ARC System: 次世代液相層析系統,提供穩定可靠的樣品分離功能。 The ACQUITY ARC is a next-generation liquid chromatography system with stable and reliable separation performance.
通識化理解: LC-MS 可先利用液相層析把混合樣品中的成分分開, 再由質譜儀依分子的質荷比進行辨識;若樣品已完成純化, 亦可採 ESI-MS 直接進樣,快速確認主要分子峰。 In simple terms, liquid chromatography first separates compounds in a mixture, and the mass spectrometer then identifies them by mass-to-charge ratio. Purified samples may also be analyzed by direct ESI-MS injection for rapid mass confirmation.
搭配 C-18 管柱分離樣品成分,降低混合物對質譜判讀的干擾。 The ACQUITY ARC with a C-18 column separates sample components before mass detection.
支援正、負離子模式,可依化合物性質選擇適合的離子化條件。 Electrospray ionization supports positive and negative modes according to compound properties.
以單四極桿分析器進行例行質量確認,適合初步定性鑑別。 The single-quadrupole detector provides routine mass confirmation for preliminary qualitative identification.
適用於小分子有機藥物的初步質量確認與定性鑑別。 Suitable for preliminary mass confirmation and qualitative identification of small organic drug molecules.
可用於天然物或其純化成分的初步質譜分析。 Applicable to preliminary mass-spectrometric analysis of natural products and purified constituents.
可作為送測高解析質譜前的必要初步分析,先確認主要質量訊號。 Provides preliminary screening and major-mass confirmation before high-resolution mass spectrometry.
適合進行例行分子質量確認。 Suitable for routine molecular-mass confirmation.
可依樣品離子化特性選擇 ESI+ 或 ESI− 模式進行分析。 Samples may be screened in ESI+ or ESI− mode according to their ionization characteristics.
可先利用 C-18 管柱分離混合樣品,再進行質譜定性分析。 Mixed samples can be separated on a C-18 column before qualitative mass analysis.
先以液相層析分離樣品,再由質譜儀確認主要質量訊號。 The sample is separated by liquid chromatography before major mass signals are confirmed by mass spectrometry.
樣品直接送入質譜儀進行質譜搜尋;直接進樣前須先完成純化。 Samples are introduced directly into the mass spectrometer; purification is required before direct injection.
請使用 HPLC 或光譜級低極性有機溶劑,例如甲醇,進行樣品稀釋。 Dilute samples with HPLC- or spectroscopy-grade low-polarity organic solvent, such as methanol.
請使用 2 mL 樣品瓶,瓶內樣品量須大於 1 mL。 Use a 2 mL sample vial containing more than 1 mL of sample solution.
平台提供 C-18 管柱、甲醇及純水,供既定分析條件使用。 The platform provides a C-18 column, methanol, and purified water for the standard analytical conditions.
若研究需要其他管柱、溶劑或分析條件,請由申請者自行準備。 Users must provide other columns, solvents, or special analytical conditions required by their experiments.
儀器開放時間為週一至週五 08:00–17:00;申請前請先閱讀操作規範與分析流程。 Operating hours are Monday to Friday, 08:00–17:00. Read the operating guidelines and analysis workflow before applying.
委託操作由平台依送達順序處理;自行操作僅限已符合資格之使用者申請。 Staff-operated samples are processed in the order received. Self-operation is limited to qualified users.
委託者須送交申請表、樣品與過濾耗材;自行操作須至少於三個工作天前完成線上預約。 Staff-operated users submit the form, sample, and filtration materials. Self-users must reserve online at least three working days in advance.
取消規定: 自行操作者若確定無法於預約時段使用,請於前一日通知;未依規定取消者仍須收費。 Cancellation policy: notify the facility one day in advance if the reserved session cannot be used; otherwise, the applicable fee will still be charged.
請將申請表、樣品及過濾耗材送至第一教學大樓五樓 N523 室,依送達順序進行檢測。 Submit the application form, sample, and filtration materials to Building 1, 5F, Room N523. Samples are processed in the order received.
僅限符合資格之使用者申請,並須至少於三個工作天前完成線上預約。 Self-operation is available only to qualified users and requires online reservation at least three working days in advance.
ESI-MS 直接進樣樣品須於送測前完成純化。 Samples must be purified before direct ESI-MS injection.
建議以 HPLC 或光譜級低極性有機溶劑稀釋至 10−5–10−7 M。 Dilute samples to 10⁻⁵–10⁻⁷ M using HPLC- or spectroscopy-grade low-polarity organic solvent.
請使用 2 mL 樣品瓶,瓶內裝液量須大於 1 mL。 Use a 2 mL sample vial with a fill volume greater than 1 mL.
平台僅提供 C-18 管柱、甲醇及純水;其他分析條件與材料請自行準備。 Only a C-18 column, methanol, and purified water are provided. Users must supply other conditions and materials.
| 使用者類別 / User Category | 分析服務 / Service | 操作方式 / Mode | 收費標準 / Fee |
|---|---|---|---|
| 校內使用者 Internal Users | LC-MS 定性鑑定 | 委託操作 / Staff-operated | NT$ 200/件 |
| 校內使用者 Internal Users | LC-MS 定性鑑定 | 自行操作 / Self-operation | NT$ 200/小時 |
| 校內使用者 Internal Users | ESI 直接進樣 | 委託操作 / Staff-operated | NT$ 200/件 |
| 校外使用者 External Users | LC-MS 定性鑑定 | 委託操作 / Staff-operated | NT$ 1,500/件 |
| 校外使用者 External Users | ESI 直接進樣 | 委託操作 / Staff-operated | NT$ 1,500/件 |
| 育成中心進駐廠商 Incubation Center Tenant | LC-MS 定性鑑定 | 委託操作 / Staff-operated | NT$ 1,200/件 |
| 育成中心進駐廠商 Incubation Center Tenant | ESI 直接進樣 | 委託操作 / Staff-operated | NT$ 1,200/件 |
第一教學大樓五樓 N523 室-液相層析儀分析室 Building 1, 5F, Room N523 – Liquid Chromatography Laboratory
本區提供操作規範、分析流程、申請表與詳細收費表連結,申請前請先確認最新文件內容。 This section provides the operating guidelines, analysis workflow, application form, and detailed fee table. Review the latest documents before applying.
實際收費、分析條件與服務內容如有調整,請以管理單位最新公告為準。
Actual fees, analytical conditions, and services are subject to the latest announcement from the responsible unit.